50 Ω coax attenuation chart
Add cables, set each length, and compare total loss across frequency.
| Cable | Length | Loss at spot (dB) | Power out | Total at 50 MHz | at 150 MHz | at 1 GHz |
|---|
Values are typical manufacturer datasheet figures (dB/100 m at 50 MHz, 150 MHz and 1 GHz; where 150 MHz isn’t published, it is interpolated from the neighbouring points), fitted with a √f + f loss model, so they are most accurate between about 10 MHz and 3 GHz. The same cable type varies by maker (RG-58 is 55–70 dB/100 m at 1 GHz, depending on the datasheet), so the maker is named where it matters. * marks provisional values: Magnum RG-213 uses the 4.5 dB at 50 MHz from its datasheet, with 150 MHz and 1 GHz extrapolated from the MIL-C-17/93G curve, and RG-213 MIL-C-17 uses typical Cavel figures because its file couldn’t be read. Real cables vary by manufacturer, age and connectors; always check the datasheet for critical work. Connector and mismatch losses are not included.